The sensor is ATEX approved to Ex II 1GD EEx ia IIC T4 Ex iaD 20 T135°C (Ta = -40°C to +80°C). This designates the sensor as belonging to; Group II: suitable for all areas except mining, Category 1 GD: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas (Zones 2 to 0) and dust (Zone 20).
Gas:
Protection class ia, denotes intrinsically safe for all zones.
Apparatus group IIC: suitable for IIA, IIB and IIC
explosive gases.
Temperature class T4: maximum sensor surface
temperature under fault conditions 135°C.
Dust:
T135°C: maximum sensor surface temperature under
fault conditions 135°C.
Ambient temperature range extended to -40°C to
+80°C. |