This sensor is ATEX approved to
I/II M1/1GD EEx ia IIC T4 Ex iaD 20 T135°C (Ta = -40°C to +80°C).
This
designates the sensor as belonging to; Groups I and II: suitable for all
areas (including mining),
Category M1/1 GD: can be used in areas with continuous, long or frequent
periods of exposure to hazardous gas (Zones 2 to 0) and dust (Zone 20),
equipment remains energised.
Gas:
Protection
class ia, denotes intrinsically safe for all zones.
Apparatus
group IIC: suitable for IIA, IIB and IIC
explosive
gases.
Temperature
class T4: maximum sensor surface
temperature
under fault conditions 135°C.
Dust:
T135°C:
maximum sensor surface temperature under
fault
conditions 135°C.
Ambient
temperature range extended to -40°C
to
+80°C.
|