| Dimensions |
|
|
Body Diameter
|
35mm |
|
Body Length (to seal face)
|
43mm (5V input) - 48mm (Other
inputs) |
|
Probe Length (from seal face)
|
Measurement length
+ 58mm |
|
Target Tube Length
|
Measurement length +30mm, ID
7.7mm, OD 9.45mm |
|
|
|
|
Travel
|
any stroke from 20 mm to 600mm
(eg 305mm) |
|
Independant Linearity
|
<±0.25% up to 450mm <±0.50%
over 450mm at 20°C |
|
Temperature Coefficient
|
<±0.01%/°C Gain &
<±0.01%FS/°C Offset |
|
Typical Overall Accuracy
|
<±0.75%/FSO
 |
|
Resolution
|
Infinite |
|
Noise
|
<0.02% FSO |
|
Frequency Response
|
>10KHz (-3dB); |
|
>300Hz (-3dB); 2 wire 4-20mA |
|
|
|
|
Output Signal and Output Load
|
| Output Signal |
Output Load |
|
|
|
| 0.5 to 4.5 V dc ratiometric |
2 K Ohms min |
|
|
|
| 0.5 to 4.5 V dc |
2 K Ohms min |
|
|
|
|
|
|
|
|
|
| 0.5 to 9.5 V dc |
5 K Ohms min |
|
|
|
| 4 to 20mA (2 wire) |
300 Ohms @ 24V |
|
|
|
| 4 to 20mA (3 wire sink) |
950 Ohms @ 24V |
|
|
|
| 4 to 20mA (3 wire source) |
300 Ohms Max |
|
|
Supply Current
|
| 12 mA Typical 20 mA max. (Voltage Versions) |
|
|
|
|
|
|
Temperature Limits
|
|
|
Operating
|
-40 to +125°C (5V input
only) |
|
-20 to +85°C |
|
Storage
|
-40 to +125°C |
|
EMC Performance
|
|
|
Susceptibility
|
EN 61000-6-2 |
|
Radiated
|
EN 61000-6-3 |
|
|
|
|
Vibration
|
IEC 68-2-6: 10g |
|
Shock
|
IEC 68-2-29: 40 g |
|
MTBF
|
350,000 hrs 40°C Gf |
|
Hydraulic Pressure
|
350 Bar |
|
Sealing
|
IP65(connector) / IP67(cable) |
|
|
|
|
Electrical Connections
|
Screened 3 core cable or integral
connector |
|
Target
|
A non-magnetic target tube is
supplied with the sensor. This can be eliminated if the piston
rod is made from non-magnetic steel and is drilled to a specified
tolerance. |
|
Dimensions
|
Refer to drawings below. |
|
Outline
|
Request
AutoCAD Drawing |
|
Typical Installation in Cylinder
|
Request
AutoCAD Drawing |
|
Sealing Details
|
Request
AutoCAD Drawing |
|
Target Details Fitting
|
Request
AutoCAD Drawing |