Intrinsic Safety
|
|
|
ATEX approval
|
The
sensor is ATEX approved to II 1G EEx ia IIC T4 (Ta = -40°C to +80°C). This designates the sensor as belonging
to; Group II: suitable for all areas except
mining, Category 1 G: can be used in areas with continuous,
long or frequent periods of exposure to hazardous gas (Zone 0).
Protection class ia, denotes intrinsically safe for all zones.
Apparatus group IIC: suitable for IIA to IIC explosive gas.
Temperature class T4: maximum sensor surface temperature under fault
conditions 135°C. Ambient temperature range extended to -40°C to 80°C.
|
|
Galvanic Isolation Amplifier
|
Intrinsically safe sensors must be used with a galvanically isolated amplifier
with safety parameters not exceeding:- Ui: 11.4V, Ii:
0.2A, Pi: 0.51W. Sensor can be installed with a cable length up to
1000m maximum from the amplifier, capacitance and inductance can be up to:-
Capacitance: 550 nF max, Inductance: 99 μH max.
Approved amplifiers
are available from Positek; there is a
choice of 0.5-9.5V or 4-20mA transmission outputs.
|
|
Sensor Specification
|
|
|
Dimensions
|
|
|
Body Diameter
|
35mm
|
|
Body Length
(Axial Version)
|
Measurement length + 163mm
|
|
Body Length
(Radial Version)
|
Measurement length + 186mm
|
|
Push Rod
Extension
|
Measurement length + 7mm
|
|
Push Rod Outside Diameter
|
12.7mm
|
|
Travel
|
any stroke from 50 mm to 600mm (eg 305mm)
|
|
Independant Linearity
|
<±0.25% up to 450mm <±0.50% over 450mm
at 20°C
|
|
Temperature Coefficient
|
<±0.01%/°C Gain &
<±0.01%FS/°C Offset
|
|
Resolution
|
Infinite
|
|
Noise
|
<0.02% FSO
|
|
Frequency Response
|
>10KHz (-3dB)
|
|
|
|
|
Temperature Limits
|
|
|
Operating
|
-40 to +80°C
|
|
Storage
|
-40 to +125°C
|
|
EMC Performance
|
|
|
Susceptibility
|
EN 61000-6-2
|
|
Radiated
|
EN 61000-6-3
|
|
|
|
|
Vibration
|
IEC 68-2-6: 10g
|
|
Shock
|
IEC 68-2-29: 40 g
|
|
MTBF
|
350,000 hrs 40°C Gf
|
|
Sealing
|
IP65(connector) / IP67(cable)
|
|
|
|
|
Electrical Connections
|
Screened 3 core cable or integral connector
|
|
Detailed Dimensions
|
Refer to drawings below. Other options available.
|
|
Galvanically Isolated Amplifier
|
|
|
Outline
|