| Intrinsic
Safety |
|
|
ATEX approval
|
The
sensor is ATEX approved to II 1G EEx ia IIC T4 (Ta = -40°C
to +80°C). This designates the sensor as belonging
to; Group II: suitable for all areas except
mining,
Category 1 G: can be used in areas with continuous, long or
frequent periods of exposure to hazardous gas (Zone 0).
Protection
class ia, denotes intrinsically safe for all zones.
Apparatus group IIC: suitable for IIA to IIC explosive gas.
Temperature class T4: maximum sensor surface temperature under
fault conditions 135°C. Ambient temperature range
extended to -40°C to 80°C.
|
|
Galvanic Barrier
|
Intrinsically
safe sensors must be used with a galvanically isolated barrier
with safety parameters not exceeding:- Ui: 11.4V, Ii: 0.46A,
Pi: 0.51W. Sensor can be installed with a cable length
up to 150m maximum from the barrier, capacitance and inductance
can be up to:- Capacitance: 550 nF max, Inductance: 99 μH
max.
Approved
barriers are available from Positek; there is a
choice
of 0.5-9.5V or 4-20mA transmission
outputs. The sensor is calibrated to suit the selected barrier
transmission output.
|
| Sensor
Specification |
|
| Dimensions |
|
|
Body Diameter
|
19mm |
|
Body Length (Axial Cable Version)
|
Measurement length + 134mm |
|
Body Length (Axial Connector Version)
|
Measurement length
+ 134mm |
|
Body Length (Radial Cable Version)
|
Measurement length + 139mm |
|
Body Length (Radial Connector Version)
|
Measurement length + 142mm |
|
Travel
|
any stroke from 10 mm to 300mm
(eg 205mm) |
|
Independant Linearity
|
<±0.25% @ 20°C |
|
Temperature Coefficient
|
<±0.01%/°C Gain
& <±0.01%FS/°C Offset |
|
Typical Overall Accuracy
|
<±0.50%
FSO  |
|
Resolution
|
Infinite |
|
Noise
|
<0.02% FSO |
|
Frequency Response
|
>10KHz (-3dB) |
|
|
|
Temperature Limits
|
|
|
Operating
|
-40 to +80°C |
|
Storage
|
-40 to +125°C |
|
EMC Performance
|
|
|
Susceptibility
|
EN 61000-6-2 |
|
Radiated
|
EN 61000-6-3 |
|
|
|
|
Vibration
|
IEC 68-2-6: 10g |
|
Shock
|
IEC 68-2-29: 40 g |
|
MTBF
|
350,000 hrs 40°C Gf |
|
Sealing
|
IP67 |
|
|
|
|
Electrical Connections
|
Screened 3 core
cable or integral connector |
|
Detailed Dimensions
|
Refer to drawings below. |
|
Barrier
|
|
|
Outline
|
Request
AutoCAD Drawing |