E130 Long Stroke In-Cylinder Linear Position Sensor

ATEX & IECEx approved intrinsically safe sensors for hazardous dust environments

Linear

This sensor at a glance

Available in any measurement range from 0-400mm to 0-1485mm

Longer operating life than a potentiometer

Fast delivery options available

Body Diameter: 35mm

Sensor Mounting: In-cylinder

Sealed to IP67

Independent Linearity:
< ±0.25% up to 1000mm
< ±0.5% over 1000mm

Resolution: Infinite

Temperature range: -40° to +80°C

The intrinsically safe E130 is ATEX and IECEx approved for use in potentially explosive gas/vapour and dust atmospheres. It is designed for demanding hydraulic or pneumatic cylinder position feedback applications where service life, environmental resistance and cost are important and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas.

Overall performance, repeatability and stability are outstanding over a wide temperature range. The unit is highly compact and space-efficient, being responsive along almost its entire length. Like all Positek sensors, the E130 provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-400mm to 0-1485mm and with full EMC protection built in.

The sensor is very rugged, being made of stainless steel with an inert fluoropolymer-sheathed probe and stainless steel target tube. The sensor is easy to install in cylinders and has a range of mechanical options. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier .

Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Intrinsic Safety

ATEX/IECEx Approval

The sensor is ATEX/ IECEx approved to:
Ex II 1GD
Ex ia IIC T4 Ga (Ta = -40°C to + 80°C )
Ex ia 111C T135°C Da (Ta = -40°C to + 80°C ).
This designates the sensor as belonging to; Group II: suitable for all areas except mining, Category 1 GD: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas (Zones 2 to 0) and dust (Zone 20).

Gas:
Protection class ia, denotes intrinsically safe for all zones.
Apparatus group IIC: suitable for IIA, IIB and IIC
explosive gases.
Temperature class T4: maximum sensor surface
temperature under fault conditions 135°C .

Dust:
T135°C: maximum sensor surface temperature under
fault conditions 135°C .
Ambient temperature range extended to -40°C to +80°C .

Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.

Galvanic Isolation Amplifier

Intrinsically safe sensors must be used with a galvanically isolated amplifier with safety parameters not exceeding:- Ui: 11.4V, Ii: 0.2A, Pi: 0.51W.  Sensor can be installed with a cable length up to 1000m maximum from the amplifier, cable capacitance and inductance can be up to:- Capacitance: 200 nF max, Inductance: 810 μH max.

Approved amplifiers are available from Positek; there is a
choice of 0.5-9.5V or 4-20mA transmission outputs.


Dimensions

Body Diameter
35mm
Travel
Any stroke from 0-400mm to 0-1485mm (e.g. 1200mm)
Independent Linearity

<±0.25% up to 1000mm
<±0.50% over 1000mm at 20°C

Temperature Coefficient
<±0.01%/°C Gain & <±0.01%FS/°C Offset
See Graph
Resolution
Infinite
Noise

<0.02% FSO

Frequency Response

>10KHz (-3dB)


Temperature Limits

Operating
-40 to +80°C
Storage
-40 to +125°C


Other

EMC Susceptibility
EN 61000-6-2
EMC Radiated
EN 61000-6-3
Vibration
IEC 68-2-6: 10g
Shock
IEC 68-2-29: 40g
MTBF
350,000 hrs 40°C Gf
Hydraulic Pressure
350 Bar
Sealing
IP67
Electrical Connections
Screened cable or integral connector
Target
A non-magnetic target tube fitted with a flange is supplied with the sensor.

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:


Measurement Range

Factory set to any length from 0-400mm to 0-1485mm in increments of 1mm. For example, if your application requires 40" (1016mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 1016 mm.


Connector/Cable Options

Option
Option Code
Connector - Hirschmann GD series Axial, IP65
J
Connector - Axial IP67, M12 - 4 pin. Without trim adjustment
J + Z600
Connector - Axial IP67, M12 - 4 pin. With trim adjustmentJ + Z601
Cable with short gland Axial, IP67
M (3 core cable)
MQ (5 core cable)
(click for more information)
Cable with M12 gland Axial, IP67
L (3 core cable)
LQ (5 core cable)
(click for more information)
Cable length - The standard length of cable supplied with a Positek position sensor is 50cm although you can specify any length you require up to a maximum of 15,000cm
Specified in cm after the L/LQ or M/MQ e.g. L200 for 200cm cable from axial cable gland


Mounting Thread Size Options

Option
Option Code
M18
T
M20
N
3/4" UNF
P


Target Flange Options

Option
Option Code
'Circlip Fit' style
V
'Screw Fit' style
W

Click Here for approved Galvanic Isolation Amplifier Options


Galvanic Isolation Amplifier
Click for PDF
Outline
Click for PDF
Request AutoCAD Drawing
Typical Installation in Cylinder
Click for PDF
Sealing Details
Click for PDF
Datasheet
Click for PDF
Installation Sheet
Click for PDF


image missing