X623 Submersible IP68 350bar Large Angle Tilt Sensor

ATEX & IECEx approved intrinsically safe underwater sensor for hazardous gas environments

Underwater

This sensor at a glance

Available in any measurement range from 15 to 160°

Longer operating life than a potentiometer

Fast delivery options available

Body Diameter: 40mm

Sensor Mounting: Flange

Fast settle time

Sealed to IP68 350bar, 3500msw, 5000psi

Independent Linearity/Hysterisis (combined error):
< ±0.25° up to 100°

Resolution: Infinite

Temperature range: -4 to +50°C

The intrinsically safe 350 bar X623 tilt sensor is ATEX and IECEx approved for use in potentially explosive gas/vapour atmospheres. It is designed for continuous underwater applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas. The X623, like all Positek sensors, is supplied with the output calibrated to the angle required by the customer, between 15 and 160 degrees and with full EMC protection built in. The sensor provides a linear output characteristic with angle of deflection. There is a machined registration mark to identify the calibrated mid point.

Overall performance, repeatability and stability are outstanding over a wide temperature range.

It is sealed to IP68 350bar (5000psi, 3500m depth).

The sensor has a rugged stainless steel body and mounting flange.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Intrinsically Safe

ATEX/IECEx approval
The sensor is ATEX/IECEx approved to:
Ex II 1G
Ex ia IIC T4 GA (Ta = -40°C to +80°C).
This designates the sensor as belonging to; Group II: suitable for all areas except mining, Category 1 G: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas (Zone 0). Protection class ia, denotes intrinsically safe for all zones. Apparatus group IIC: suitable for IIA to IIC explosive gas. Temperature class T4: maximum sensor surface temperature under fault conditions 135°C. Ambient temperature range extended to -40°C to 80°C.
Approval only applies to the specified ambient temperature range and atmospheric conditions in the range 0.80 to 1.10 Bar, oxygen <=21%.
Galvanic Isolation Amplifier

Intrinsically safe sensors must be used with a galvanically isolated amplifier with safety parameters not exceeding:- Ui: 11.4V, Ii: 0.2A, Pi: 0.51W.  Sensor can be installed with a cable length up to 1000m maximum from the amplifier, cable capacitance and inductance can be up to:- Capacitance: 200 nF max, Inductance: 810 μH max.

Approved amplifiers are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.


Dimensions

Body Diameter
40mm
Body Length (to seal face)
81mm
Measurement Range
Any angle from ±7.5° to ±80°
Independent Linearity/Hysterisis (combined error)
<±0.25°
Temperature Coefficient
<±0.01%/°C Gain & <±0.01%FS/°C Offset
Response Time
250mS at 20°C typical
Damping Ratio
0.2:1 (0.6 nom at 25°C)
Resolution
Infinite
Noise

<0.02% FSO


Temperature Limits

Operating
-4 to +50°C
Storage
-4 to +50°C


Other

EMC Susceptibility
EN 61000-6-2
EMC Radiated
EN 61000-6-3
Vibration
IEC 68-2-6: 10g
Shock
IEC 68-2-29: 40g
MTBF
350,000 hrs 40°C Gf
Sealing
IP68 350bar, 5000psi, 3500m
Electrical Connections
Micro wet mate connector

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:


Measurement Range

Factory set to any length from ±7.5° to ±80° in increments of 1°. For example, if your application requires 90° measurement, then Positek will manufacture the sensor specifically for this length. The sensor will measure 90° however will still rotate through 360°.


Connector/Cable Options

Option
Option Code
Axial micro wet mate bulkhead and mating connector with 50cm flying lead (standard fit).
Mating connector with cables are available as special
J50
Radial micro wet mate bulkhead and mating connector with 50cm flying head (standard fit).
Mating connector with longer cables available as special.
Option Code
K50


Click Here for approved Galvanic Isolation Amplifier Options


Galvanic Isolation Amplifier
Click for PDF
Outline
Click for PDF
Request AutoCAD Drawing
Datasheet
Click for PDF
Installation Sheet
Click for PDF