M114  Waterproof (IP68) Stand Alone Linear Position Sensor

ATEX & IECEx approved intrinsically safe sensors for hazardous mining environments

Underwater

This sensor at a glance

Available in any measurement range from 0-5mm to 0-800mm

Longer operating life than a potentiometer

Fast delivery options available

Body Diameter: 35mm

Sensor Mounting: M5 rod eyes, body clamps or M5 threads

Spring loaded pushrod option available

Sealed to IP68 10bar, 100msw, 145psi

Independent Linearity:
< ±0.25% up to 450mm
< ±0.5% over 450mm
< ±0.1 % option available

Resolution: Infinite

Temperature range: -40°C to +80°C

The intrinsically safe M114 is an ATEX and IECEx mining approved affordable, durable, high-accuracy position sensor. Derived from the M101, the M114 was designed for industrial and scientific feedback applications where the equipment requires IP68 sealing, it shares many of the desirable features such as compact size.

The M114, like all Positek sensors, provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-800mm and with full EMC protection built in. The sensor is very robust, the body and push rod being made of stainless steel for long service life and environmental resistance. The M114 has been designed for applications where the sensor may be completely submerged in water up to a pressure of 10Bar, but good sensor performance and cost are still important.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Intrinsic Safety

ATEX/IECEx Approval

This sensor is ATEX/IECEx approved to:
Ex I/II M1/1GD
Ex ia IIC T4 Ga (Ta = -40°C to + 80°C )
Ex ia 111C 20 T135°C Da (Ta = -40°C to + 80°C )
Ex ia I Ma (Ta = -40°C to + 80°C )
This designates the sensor as belonging to; Groups I and II: suitable for all areas (including mining), Category M1/1 GD: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas (Zones 2 to 0) and dust (Zone 20), equipment remains energised.

Gas:
Protection class ia, denotes intrinsically safe for all zones.
Apparatus group IIC: suitable for IIA, IIB and IIC
explosive gases.
Temperature class T4: maximum sensor surface
temperature under fault conditions 135°C .

Dust:
T135°C: maximum sensor surface temperature under fault conditions 135°C.

Ambient temperature range extended to -40°C to +80°C .

Galvanic Isolation Amplifier

Intrinsically safe sensors must be used with a galvanically isolated amplifier with safety parameters not exceeding:- Ui: 11.4V, Ii: 0.2A, Pi: 0.51W.  Sensor can be installed with a cable length up to 1000m maximum from the amplifier, cable capacitance and inductance can be up to:- Capacitance: 200 nF max, Inductance: 810 μH max.

Approved amplifiers are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.


Dimensions

Body Diameter
35mm
Body Length (Axial Version)
See drawing
Probe Length (Radial Version)
See drawing
Push Rod Extension
See drawing
Push Rod Outside Diameter
9.5mm
Travel
Any stroke from 0-5mm to 0-800mm (e.g. 305mm)
Independent Linearity
<±0.25% up to 450mm
<±0.50% over 450mm at 20°C
<±0.1% available on request
Temperature Coefficient
<±0.01%/°C Gain & <±0.01%FS/°C Offset
Resolution
Infinite
Noise

<0.02% FSO

Frequency Response

>10KHz (-3dB);


Temperature Limits

Operating
-40 to +80°C
Storage
-40 to +125°C


Other

EMC Susceptibility
EN 61000-6-2
EMC Radiated
EN 61000-6-3
Vibration
IEC 68-2-6: 10g
Shock
IEC 68-2-29: 40g
MTBF
350,000 hrs 40°C Gf
Sealing
IP68 10bar, 150psi, 100m
Electrical Connections
Screened cable

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:


Measurement Range

Factory set to any length from 0-5mm to 0-800mm in increments of 1mm. For example, if your application requires 10" (254mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 254mm.


Connector/Cable Options

Option
Option Code
Cable with PG9 gland Axial, Gland IP68
L (3 core cable)
LQ (5 core cable)
(click for more information)
Cable with PG9 gland Radial, Gland IP68 I (3 core cable)
IQ (5 core cable)
(click for more information)
Cable length - The standard length of cable supplied with a Positek position sensor is 50cm although you can specify any length you require up to a maximum of 15,000cm
Specified in cm after the L/LQ or I/IQ e.g. L200 for 200cm 3 core cable from axial cable gland


Mounting Options

Option
Option Code
M5 rod eye on body (only with option "I")
N
Body clamps
P
M5 rod eye on push rod
U


Push Rod Options

Option
Option Code
Spring loaded (extended) (up to 300mm storke - for longer strokes please contact Positek)
R
Spring loaded (Retracted) (up to 300mm storke - for longer strokes please contact Positek)
S
Dome end on push rod (only with option "R")
T
Non-captive push rod
V


<+/-0.1% FSO Linearity error  (≥10mm and ≤400mm stroke length) Option Code
Z650


Click Here for approved Galvanic Isolation Amplifier Options


Galvanic Isolation Amplifier
Click for PDF
Outline
Click for PDF
Request AutoCAD Drawing
Datasheet
Click for PDF
Installation Sheet
Click for PDF


image missing