M114 Waterproof (IP68) Stand Alone Linear Position Sensor
ATEX & IECEx approved intrinsically safe sensors for hazardous mining environments
This sensor at a glance
Available in any measurement range from 0-5mm to 0-800mm
Longer operating life than a potentiometer
Fast delivery options available
Body Diameter: 35mm
Sensor Mounting: M5 rod eyes, body clamps or M5 threads
Spring loaded pushrod option available
Sealed to IP68 10bar, 100msw, 145psi
Independent Linearity:
< ±0.25% up to 450mm
< ±0.5% over 450mm
< ±0.1 % option available
Resolution: Infinite
Temperature range: -40°C to +80°C
The intrinsically safe M114 is an ATEX and IECEx mining approved affordable, durable, high-accuracy position sensor. Derived from the M101, the M114 was designed for industrial and scientific feedback applications where the equipment requires IP68 sealing, it shares many of the desirable features such as compact size.
The M114, like all Positek sensors, provides a linear output proportional to displacement. Each unit is supplied with the output calibrated to the travel required by the customer, from 0-5mm to 0-800mm and with full EMC protection built in. The sensor is very robust, the body and push rod being made of stainless steel for long service life and environmental resistance. The M114 has been designed for applications where the sensor may be completely submerged in water up to a pressure of 10Bar, but good sensor performance and cost are still important.
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (X005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
Intrinsic Safety
ATEX/IECEx Approval | This sensor is ATEX/IECEx approved to: Gas: Dust: Ambient temperature range extended to -40°C to +80°C . |
Galvanic Isolation Amplifier | Intrinsically safe sensors must be used with a galvanically isolated amplifier with safety parameters not exceeding:- Ui: 11.4V, Ii: 0.2A, Pi: 0.51W. Sensor can be installed with a cable length up to 1000m maximum from the amplifier, cable capacitance and inductance can be up to:- Capacitance: 200 nF max, Inductance: 810 μH max. Approved amplifiers are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs. |
Dimensions
Body Diameter | 35mm |
Body Length (Axial Version) | See drawing |
Probe Length (Radial Version) | See drawing |
Push Rod Extension | See drawing |
Push Rod Outside Diameter | 9.5mm |
Travel | Any stroke from 0-5mm to 0-800mm (e.g. 305mm) |
Independent Linearity | <±0.25% up to 450mm <±0.50% over 450mm at 20°C <±0.1% available on request |
Temperature Coefficient | <±0.01%/°C Gain & <±0.01%FS/°C Offset |
Resolution | Infinite |
Noise | <0.02% FSO |
Frequency Response | >10KHz (-3dB); |
Temperature Limits
Operating | -40 to +80°C |
Storage | -40 to +125°C |
Other
EMC Susceptibility | EN 61000-6-2 |
EMC Radiated | EN 61000-6-3 |
Vibration | IEC 68-2-6: 10g |
Shock | IEC 68-2-29: 40g |
MTBF | 350,000 hrs 40°C Gf |
Sealing | IP68 10bar, 150psi, 100m |
Electrical Connections | Screened cable |
Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:
Measurement Range
Factory set to any length from 0-5mm to 0-800mm in increments of 1mm. For example, if your application requires 10" (254mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 254mm.
Connector/Cable Options
Option |
Option Code |
Cable with PG9 gland Axial, Gland IP68 |
L (3 core cable) LQ (5 core cable) (click for more information) |
Cable with PG9 gland Radial, Gland IP68 | I (3 core cable) IQ (5 core cable) (click for more information) |
Cable
length - The standard length of cable supplied with a Positek position
sensor is 50cm although you can specify any length you require up to a
maximum of 15,000cm |
Specified in cm after the L/LQ or I/IQ e.g. L200 for 200cm 3 core cable from axial cable gland |
Mounting Options
Option |
Option Code |
M5 rod eye on body (only with option "I") |
N |
Body clamps |
P |
M5 rod eye on push rod |
U |
Push Rod Options
Option |
Option Code |
Spring loaded (extended) (up to 300mm storke - for longer strokes please contact Positek) |
R |
Spring loaded (Retracted) (up to 300mm storke - for longer strokes please contact Positek) |
S |
Dome end on push rod (only with option "R") |
T |
Non-captive push rod |
V |
<+/-0.1% FSO Linearity error (≥10mm and ≤400mm stroke length) | Option Code Z650 |
Click Here for approved Galvanic Isolation Amplifier Options
Galvanic Isolation Amplifier | Click for PDF |
Outline | Click for PDF Request AutoCAD Drawing |
Datasheet | Click for PDF |