H133 Mid Stroke Linear Position Sensor
CSA approved intrinsically safe sensors for hazardous dust atmospheres
This sensor at a glance
Available in any measurement range from 0-51mm to 0-100mm
(for 2-50mm range see H103)
Longer operating life than a potentiometer
Fast delivery options available
Body Diameter: 35mm
Sensor Mounting: Flange
Spring loaded pushrod option available
Sealed to IP67
Independent Linearity:
< ±0.25%
< ±0.1% option available
Resolution: Infinite
Temperature range: -40°C to +80°C
Intrinsically safe H133 is CSA approved for use in potentially explosive gas/vapour and dust atmospheres. The H133 is designed for a wide range of industrial applications and is ideal for OEMs seeking good sensor performance in situations where a mid-bodied sensor is required for operation in hazardous areas. The unit is compact and space-efficient, being responsive along almost its entire length, and like all Positek® sensors provides a linear output proportional to displacement.
Each unit is supplied with the output calibrated to the travel required by the customer, from 0-51mm to 0-100mm and with full EMC protection built in.
Overall performance, repeatability and stability are outstanding over a wide temperature range.
The sensor has a rugged stainless steel body and plunger. It is easy to install and set up, the stainless steel mounting flange has two 4.5mm by 30 degree wide slots on a 48mm pitch. The plunger can be supplied free or captive, with female M4 thread, or spring-loaded with a ball end. The H133 also offers a range of mechanical options, environmental sealing is to IP67.
Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.
The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.
Intrinsic Safety
CSA Approval | This sensor is CSA approved to; Class I, Zone 0 Gas: Dust: |
Galvanic Isolation Amplifier | It
is imperative Positek® intrinsically safe sensors be used in
conjunction with a galvanic barrier to meet the requirements of the
product certification. The Positek G005 Galvanic Isolation Amplifier is
purpose made for Positek IS sensors making it the perfect choice. Refer
to the G005 datasheet for product specification and output configuration
options. The Positek® G005 Galvanic Isolation Amplifier is available with 0.5 - 9.5V or 4 - 20mA transmission output options or reverse outputs of 9.5 - 0.5 volts or 20 - 4 mA. |
Dimensions
Body Diameter | 35mm |
Body Length | See drawing |
Push Rod Outside Diameter | 6mm |
Travel | Any stroke from 0-51mm to 0-100mm (e.g. 76mm) |
Independent Linearity | <±0.25% at 20°C <±0.1% available on request |
Temperature Coefficient | <±0.01%/°C Gain & <±0.01%FS/°C Offset See Graph |
Resolution | Infinite |
Noise | <0.02% FSO |
Frequency Response | >10KHz (-3dB); |
Temperature Limits
Operating | -40 to +80°C |
Storage | -40 to +125°C |
Other
EMC Susceptibility | EN 61000-6-2 |
EMC Radiated | EN 61000-6-3 |
Vibration | IEC 68-2-6: 10g |
Shock | IEC 68-2-29: 40g |
MTBF | 350,000 hrs 40°C Gf |
Sealing | IP67 |
Electrical Connections | Screened cable or integral connector |
Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:
Measurement Range
Factory set to any length from 0-51mm to 0-100mm in increments of 1mm. For example, if your application requires 3" (76mm) measurement, then Positek will manufacture the sensor specifically for this length. The mechanical length and calibration will be set up for 76mm.
Connector/Cable Options
Option | Option Code |
Connector IP67 M12 4 pin | J |
Cable with axial gland, IP67 | L (3 core cable) LQ (5 core cable) (click for more information) |
Cable with axial short gland, IP67 | M (3 core cable) MQ (5 core cable) (click for more information) |
Cable
length - The standard length of cable supplied with a Positek position
sensor is 50cm although you can specify any length you require up to a
maximum of 15,000cm | Specified in cm after the L/LQ or M/MQ e.g. L200 for 200cm cable from axial cable gland |
Plunger Options
Option | Option Code |
Spring loaded (extented) | R |
Dome end on plunger | T |
Non-captive plunger (not with options "R" or "T") | V |
<+/-0.1% FSO Linearity error | Option Code Z650 |
Click Here for approved Galvanic Isolation Amplifier Options
Galvanic Isolation Amplifier | Click for PDF |
Outline | Click for PDF Request AutoCAD Drawing |
Datasheet | Click for PDF |