H603 Large Angle Tilt Sensor

CSA approved intrinsically safe sensors for hazardous dust atmospheres

Tilt

This sensor at a glance

Available in any measurement angle from 15 to 160°

Longer operating life than a potentiometer

Fast delivery options available

Body Diameter: 35mm

Sensor Mounting: Flange

Sealed to IP67

Independent Linearity/Hysterisis (combined error):
< ±0.25°

Resolution: Infinite

Temperature range: -20°C to +80°C

Intrinsically safe H603 is CSA approved for use in potentially explosive gas/vapour and dust atmospheres.

The H603 is designed for industrial and scientific feedback applications and is ideal for OEMs seeking good sensor performance for arduous applications in hazardous areas. The H603, like all Positek® sensors, is supplied with the output calibrated to the angle required by the customer, between 15 and 160 degrees and with full EMC protection built in. The sensor provides a linear output characteristic with angle of deflection. There is a machined registration mark to identify the calibrated mid point.

Overall performance, repeatability and stability are outstanding over a wide temperature range. Electrical connections to the sensor are made via an industrial standard 4-pin M12 connector, with limited rotational capability to facilitate cable routing.

The sensor has a rugged stainless steel body and mounting flange. The flange has two 4.5mm by 30 degree wide slots on a 48mm pitch to simplify mounting and position adjustment. Environmental sealing is to IP67.

Positek intrinsically safe sensors are designed to be used with a galvanically isolated amplifier. Approved galvanic isolation amplifiers (G005) are available from Positek; there is a choice of 0.5-9.5V or 4-20mA transmission outputs.

The sensor can be installed with a cable length up to 1km between the sensor and the amplifier.

Intrinsic Safety

CSA Approval

This sensor is CSA approved to; Class I, Zone 0
Ex ia IIC T4 (Ta = -40°C to +80°C)
AEx ia IIC T4 (Ta = -40°C to +80°C)
AEx iaD IIIC T93°C(Ta = -40°C to +80°C)
Designates the sensor as belonging to; Class I, Zone 0: suitable for all areas except mining: can be used in areas with continuous, long or frequent periods of exposure to hazardous gas or dust

Gas:
Protection class ia IIC, denotes intrinsically safe for Zones 0, 1 & 2 and IIA, IIB and IIC explosive gases.
Temperature class T4: maximum sensor surface temperature under fault conditions 135°C.

Dust:
T93°C: maximum sensor surface temperature under fault conditions 93°C.
Ambient temperature range extended to -40°C to +80°C.

Galvanic Isolation Amplifier
It is imperative Positek® intrinsically safe sensors be used in conjunction with a galvanic barrier to meet the requirements of the product certification. The Positek G005 Galvanic Isolation Amplifier is purpose made for Positek IS sensors making it the perfect choice. Refer to the G005 datasheet for product specification and output configuration options.

The Positek® G005 Galvanic Isolation Amplifier is available with 0.5 - 9.5V or 4 - 20mA transmission output options or reverse outputs of 9.5 - 0.5 volts or 20 - 4 mA.


Dimensions

Body Diameter
35mm
Body Length (to seal face)
44mm
For full mechanical details see drawing
Measurement Range
Any angle from ±7.5° to ±80°
Independent Linearity/Hysterisis (combined error)
<±0.25°
Temperature Coefficient
<±0.01%/°C Gain & <±0.01%FS/°C Offset
Output Characteristics
See Graph
Response Time
250mS at 20°C typical
Damping Ratio

0.2:1 (0.6 nom at 25°C)

Resolution

Infinite

Noise

<0.02% FSO


Temperature Limits

Operating
-20 to +80°C
Storage
-40 to +125°C


Other

EMC Susceptibility
EN 61000-6-2
EMC Radiated
EN 61000-6-3
Vibration
IEC 68-2-6: 10g
Shock
IEC 68-2-29: 40g
MTBF
350,000 hrs 40°C Gf
Sealing
IP67
Electrical Connections
Integral connector

Positek offers a range of options for its standard sensors. Each sensor is manufactured to suit each customer's preferences. If your requirement is outside the options given below, Positek can modify/ redesign a sensor to suit your specific requirement. Standard options are available as below:


Measurement Range

Factory set to any length from ±7.5° to ±80° in increments of 1°. For example, if your application requires 90° measurement, then Positek will manufacture the sensor specifically for this angular range. The sensor will measure 90° however will still rotate through 360°.


Click Here for approved Galvanic Isolation Amplifier Options


Galvanic Isolation Amplifier
Click for PDF
Outline
Click for PDF
Request AutoCAD Drawing
Datasheet
Click for PDF
Installation Sheet
Click for PDF


image missing